20 kW Generators

20 RCA

Our most popular generators for backup power provide award-winning reliability and performance. When you lose power during an outage or storm, a hard-working 14/20 kW KOHLER® generator keeps your appliances working, the heat or AC running and your security system on. Now also available in 3 phase.


Model Number: 20RCA

$5205.00* MSRP

Specifications

PEAK MOTOR STARTING kVA @ 240 V 41 kVa
ALTERNATOR NOTE All information shown is for 1 Phase 60 Hz generator with the largest alternator option available.
DISPLACEMENT 999 cm³ (61 cu. in.)
HORSEPOWER NG 27.1 HP, LP 30.9 HP
ENCLOSURE MATERIAL Aluminum
SOUND OUTPUT DURING WEEKLY EXERCISE 64 dB(A)
SOUND OUTPUT DURING FULL SPEED 69 dB(A)
WARRANTY Premium five-year limited warranty
ALTERNATOR TYPE 2-Pole, Rotating Field
COUNTRY OF ORIGIN US
CERTIFICATIONS/LISTINGS EPA|CSA|UL 2200|cUL
AUTOMATIIC TRANSFER SWITCH INCLUDED Sold Separately
REMOTE MONITORING AVAILABLE Included
OFF GRID/UTILITY BACKUP Utility Backup
WEIGHT 555 lbs. (252 kg)
FUEL CONSUMPTION ON NG AT 50% LOAD 161 cfh
FUEL CONSUMPTION ON LP AT 50% LOAD 82 cfh
MANETTE RDC2 Controller
CYLINDER ARRANGEMENT V-2
DIMENSIONS 1193 mm x 666 mm x 817 mm (47 in. x 26.2 in. x 32.2 in.)
ENGINE MANUFACTURER/DESCRIPTION KOHLER
ENGINE MODEL CH1000
FUEL TYPE LPG|Natural Gas
FREQUENCY 60 Hz
PHASE Single Phase or Three Phase
VOLTAGE @ 60 HZ 120/240|277/480
DIGITAL VOLTAGE REGULATION ±1.0%
BUILT IN MOUNTING PAD Yes

*Starting price in US dollars. Does not include installation, automatic transfer switch, accessories or costs to export outside the US.




20 RCAL

Popular generators for backup power, with an automatic transfer switch included. When you lose power during an outage or storm, a hard-working 20 kW KOHLER® generator keeps your appliances working, the heat or AC running and your security system on.


Model Number: 20RCAL

$6070.00* MSRP

Specifications

Weight (lbs) 611
Weight (kg) 277
Dimensions 1193 mm x 666 mm x 817 mm (47 in. x 26.2 in. x 32.2 in.)
Controller RDC2 Controller
Frequency Hertz60
Alternator Type 2-Pole, Rotating Field
Engine Manufacturer KOHLER
Fuel Type FuelTypeNaturalGasLPG
ATS Included? Included
Cooling Type ProductCoolingAir
Cylinder Arrangement V-2
Displacement 999 cm³ (61 cu. in.)
Engine Model CH1000
Engine RPM 3600
Off-Grid Support UtilityBackup
Remote Monitor Included
Phase SinglePhase,ThreePhase
Rated kW 20
Voltage 120/240|277/480
Gas Consumption (50% load) 161 cfh
LP Consumption (50% load) 82 cfh
LP Amps 83 amps
NG Amps 75 amps
Horsepower NG 27.1 HP, LP 30.9 HP
Peak Motor Starting kVA 41 kVa
Rated LP kW 20 kW
Rated NG kW 18 kW
Sound Level (Full Speed) 69 dB(A)
Sound Level (Weekly Exercise) 64 dB(A)
Voltage Regulation (Full Load) ±1.0%

*Starting price in US dollars. Does not include installation, automatic transfer switch, accessories or costs to export outside the US.